EPGF51/EPGF52/EPGF53 winding pipe
- Describe
-
Physical, mechanical and electrical properties
Serial Number
Indicator Name
Unit
Test Method
EPGF51 Ordinary type
EPGF52 high temperature type
EPGF53 flame retardant type
1
Density
g/cm3
GB/T 5132.2-2009
IEC 61212.2:2006
≥ 1.70
≥ 1.70
≥ 1.70
2
interlayer bonding strength
MPa
≥100
≥100
≥100
3
axial compression strength
MPa
≥150
≥150
≥150
4
Vertical layer bending strength
under normal
MPa
≥400
≥400
≥400
After 155 ℃
-
≥ 200
-
5
Insulation resistance after water immersion Insulation resistance after water immersion
Ω
≥ 1.0 × 109
≥ 1.0 × 109
≥ 1.0 × 109
6
The vertical layer to the electric field intensity.
(90 2)℃ in transformer oil
Kv/mm
See Table "Vertical Layer to Electrical Strength"
7
Parallel layer to breakdown voltage
(90 2)℃ in transformer oil
kV
≥40
≥40
≥40
8
Withstand voltage along the surface after damp (5min)
kV
GB/T 23100-2008
≥12
≥12
≥12
9
Dielectric loss factor at power frequency
-
IEC 61212.2:2006
GB/T5132.2-2009
≤ 5.0 × 10-2
≤ 5.0 × 10-2
≤ 5.0 × 10-2
10
Dielectric relative permittivity at power frequency
-
5.2±0.2
5.2±0.2
5.2±0.2
11
Temperature Index (T. I)
-
≥ 130
≥ 155
≥ 130
12
water absorption
%
0.2
0.2
0.2
13
Combustibility
Level
--
--
V0
14
Partial discharge
PC
GB/T 7354-2003
≤ 5
≤ 5
≤ 5
Note 1: For interlayer bonding strength, it is only applicable to tubes with inner diameter not more than 100mm. Note 2: The height of the sample for partial discharge test is 25.0mm ± 0.2mm, and the recommended applied electric field strength is 200 V/mm ~ 300 V/mm.
Vertical layer direction electrical strength
Nominal wall thickness/mm
Electrical strength KV/mm,1min withstand voltage or 20s step-by-step boost test
EPGF51
EEPGF52
PGF53
1.0
≥ 11.6
1.2
≥ 11.0
1.4
≥ 10.4
1.6
≥ 9.8
1.8
≥ 9.4
2.0
≥ 9.0
2.2
≥ 8.7
2.4
≥ 8.4
2.6
≥ 8.1
2.8
≥ 7.9
≥3.0
≥ 7.7
keyword: