• DF204 Epoxy Glass Cloth Laminate
DF204 Epoxy Glass Cloth Laminate
+

DF204 Epoxy Glass Cloth Laminate

Product features: DF204 epoxy glass cloth laminate is made by impregnating alkali-free glass cloth treated with silane coupling agent with epoxy resin and hot pressing. It is an F-class epoxy glass cloth laminate produced according to the requirements of the IEC60893-3-2 "Specification for Industrial Rigid Laminates of Thermosetting Resins for Electrical Use". It has the characteristics of high mechanical strength at medium temperature or hot state, good electrical performance at high humidity, high breakdown voltage in parallel layer direction, flame retardant, etc. Application areas: DF204 epoxy glass cloth laminate is suitable for Class F motors, electrical equipment as insulation structural parts and other uses with insulation and flame retardant requirements. Thickness range: 0.2mm--100mm Main dimensions: 1500mm * 3000mm, 1220mm * 3000mm, 1020mm * 3000mm, 1020mm * 2440mm, 1220mm * 2440mm, 1500mm * 2440mm, 1000mm * 2000mm, 1200mm * 2000mm and other sizes based on the agreement between the supply and demand sides.

Classificationn:

  • Describe
  • Corresponding standard models and characteristics

    Product Model

    Application and Feature Classification

    Temperature resistance grade

    Deaver.

    GB/IEC

    NEMA

    DF204

    EPGC204

    -

    Similar to DF203, with better flame retardancy

    Class F 155 ℃

    Physical, mechanical and electrical properties

     

     

     

    Serial Number

    Indicator Name

    Unit

    DF204/ EPGC204

    Test Method

    Index value

    Typical value

    1

    Water absorption (T = 3mm)

    mg

    ≤ 22

    9.4

    GB/T 1303.2-2009

    2

    Vertical layer bending strength (longitudinal)

    Normal

    MPa

    ≥ 340

    540

    150 ℃ ± 3 ℃

    ≥ 170

    290

    3

    Parallel layer impact strength (simply supported beam, notch)

    kJ/m2

    ≥ 33

    70

    4

    Vertical layer direction electrical strength

    (90 ℃ ± 2 ℃ in transformer oil)(T = 1mm)

    kV/mm

    ≥ 14.2

    26.5

    5

    parallel layer directional breakdown voltage

    (90 ℃ ± 2 ℃ in transformer oil)

    kV

    ≥ 35

    >80

    6

    Dielectric Loss Factor (1MHz)

    -

    ≤ 0.04

    0.02

    7

    Dielectric constant (1MHz)

    -

    ≤ 5.5

    4.4

    8

    Insulation resistance (after immersion for 24h)

    Ω

    ≥ 5.0 × 1010

    1.7 × 1013

    9

    Combustibility

    Level

    V-0

    V-0